4-193. DIVERTER VALVE - Continued
b. Installation.
(1) Attach wires to solenoid to top of valve. Remove tags.
(2) Secure valve (2) with three screws (5), washers (4) and nuts (3).
(3) Connect eight hoses (1) to valve (2). Remove tags.
c.
Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
(2) Check operation of valve and inspect hose connections for leaks (see para 2-14).
4-489