TM 5-4210-233-14&P-1
4-175. OUTRIGGER WARNING LIGHTS - Continued
d. Installation/Assembly Inside Light
(1) Install fixture (2) (if removed) by connecting wires (7) with butt splice (Item 27, Appendix E) and
securing fixture (2) with nut (6).
(2) Install bulb (5).
(3) Install lens (3) and gasket (4) on either side with 3 screws (1).
e. Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
(2) Test operation of lights.
(3) Retract outriggers (see para 2-14).