TM 5-4210-233-14&P-1
4-122. CURRENT TRANSFORMER -Continued.
(3) Tag and cut wires to transformer (4).
(4) Remove two screws (6), four washers (7), two lockwashers (8), two nuts (9), to remove transformer (4).
b. Installation.
(1) Install transformer (4) with two screws (6), four washers (7), two lockwashers (8) and two nuts (9).
(2) Install new butt splices (Item 27, Appendix E) and connect wires to transformer (2).
(3) Loop wire (3) through transformer (4) one turn and connect wire (3) to circuit breaker terminal with
screw (5).
c.
Follow-on Maintenance.
(1) Connect batteries (see para 4-114).
4-378