4-32. METERING VALVE DRAIN
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para. 2-12.)
(Appendix B. Section III, Item 1)
APU Shutdown (see para. 2-16.)
All Piping Drained (see para. 2-17.)
MATERIALS/PARTS REQUIRED
Batteries Disconnected (see para. 4-114.)
Pipe Sealant (Item 2, Appendix E)
Grease (Item 17, Appendix E)
a. Removal.
(1) Tag and remove hoses (1).
(2) Turn nut (3) counterclockwise until free from housing (4).
(3) Turn knob (2) counterclockwise until needle (5) is free from housing (4).
(4) Remove knob (2), nut (3), and needle (5) from housing (4) as assembly.
(5) Remove nut (6), washer (7), internal tooth washer (8) and housing (4) from panel.
(6) Note position and remove fittings (9) from housing (4).
(7) Loosen set screw (10).
(8) Remove knob (2) and nut (3) from needle (5).
4-198