THERMOSTAT AND HOUSING REPLACEMENT.
Up
TM-5-4210-224-14-P 250 6PM Mini-Pumper Firefighting Truck Model No.:CM-KFT-3 Manual
Next
REMOVAL - TM-5-4210-224-14-P0216
TM 5-4210-224-14&P
4-79. THERMOSTAT AND HOUSING REPLACEMENT. (Continued)
a. Remove bolts (1).
b. Remove crossover (6).
c. Remove the studs (7) and the water outlet (8).
d. Remove the thermostat (9) from its housing.
e. Remove and discard the old gasket (10).
NOTE
Thermostat and water outlet are attached to
f. Fill the radiator with proper coolant (paragraph
the crossover along with the thermal bypass
nipple.
g. Position new gaskets (2) and install crossover
(6) with bolts (1).
INSTALLATION
h. Torque bolts to 35 ft-lbs (47 N.m).
a. Install the thermostat (9) into its housing.
i. Install heater hose, upper radiator hose and
b. Install a new gasket (10).
bypass hose (paragraph 4-77).
c. Install the water outlet (8) with the studs (7).
j. Install crankcase depression regulator valve
d. Torque the studs to 35 ft-lbs (47 N-m).
k. Fill the cooling system with coolant (paragraph
e. Connect  the  upper
radiator
inlet
hose
4-120