TM 5-4210-224-14&P
4-68. PIPING REPLACEMENT. (Continued)
b. Remove pipe.
INSTALLATION
a. Position piping and install with new teflon tape
or pipe joint compound.
b. Install street side pump panel. (paragraph 4-39)
4-69. PRIMING PUMP ASSEMBLY REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP:
Tools
Equipment Condition
General Mechanics Tool Kit
Para.  Condition Description
Street Side Pump Panel
Materials/Parts
Removed
Priming Pump (VGEAI/G158AI)
General Safety Instructions
Engine OFF
Transmission in (N) neutral.
Parking brake and micro-brakelock set.
Batteries disconnected.
REMOVAL
a. Tag and remove all connections from priming
pump (1).
b. Remove two nuts (2), washers (3), lockwashers
(4), and screws (5) from housing (1).
c. Remove priming pump (1) from mounting
bracket (6).
4-105